Model No.Range | 0 to 20 PPM , |
Resosution | 0.1 PPM |
Accuracy | 0.2 PPM+- 1Digit |
Temp Range | 0 to 100oC |
Complete with Gold / Silver D.O. Probe, Temperature Probe, D.O. Membrane 30 No. |
Specification | 1226001 | 1226002 | 1226003 |
Display | 3 Digit LED | 16x2 Alphanumeric LCD | 3 digit LED |
Wavelength | 400-700 nm | 400-700 nm | 400-700 nm |
% Transmession | 0 to 100% T | 0 to 100% T | 0 to 100% T |
Absorbance | 0 to 1.99 A | 0 to 1.99 A | 0 to 1.99 A |
Resolution | 1% T, 0.01 Abs | 1% T, 0.01 Abs | 1% T, 0.01 Abs |
Key Board | 2 Key Soft touch | 2 Key soft Touch | N.A. |
Auto Zero Facility | Available | Available | Available |
Light Source | 6.8V, 0.3 Amp. Tungsten lamp all model | ||
Sample System | 10 nm path Glass Test Tube all model | ||
Mini. Sample Volume | 1 ml for all model | ||
Filters | 400, 420,480, 500,520, 540,620,680 nm all model | ||
Power Supply | 230 volts AC supply +- 10% 50 Hz |
Specification | 1226501 | 1226502 | 1226503 |
Tele Thermometer | TeleThermometer | Microprocessor | |
6 Channels LED | Single Channels | Simultaneous Display | |
Display | 3 digit LED | 3 Digit LED | 16x2 Alphanumeric LCD |
Range | 320C to 450C | ||
Resolution | 0.1 0C | ||
Accuracy | +-1% FS +-1 Digit | ||
Sensor Type | Grade A PT 100 , Platinum Sensor | ||
Veterinary Probe | 6 No. | 1 Nos | 6 Nos. |
Rs 232C Printer | N.A. | N.A. | Window based dedicated Software to transfer data to PC |
Power Supply | 230Volts AC supply +- 10%, 50 Hz AC |
Specification | Na | K | Ca | Li |
Range | 0 to 100 ppm | 0 to 100ppm | 15 to 100ppm (Optional) | 10 to 100 ppm (Optional) |
Sensitivity | 5 ppm | 5 ppm | 10 ppm Optional | |
Readout | 21/2 Digit Bright Red LED Display | |||
Display | Single & Dual Display | |||
Accuracy | +-2%upto 40 ppm, +-5% above 40 ppm | |||
Ignition System | Auto Ignition | |||
Measuring System | Measure one element at a time | |||
Repeatability | +- 2 Count | |||
Detector | Silicon Photo Diode | |||
Filters | Narrow Band Interface Glass Filters | |||
Nebulizer | Black Bakelite, Axial Flow Type | |||
Flame System | LPG and Dry oil free air | |||
Warm up time | 10 Minutes | |||
Power Supply | 230v+- 10% AC 50 Hz |
Display | Array of 1 LED in Line |
Sample size | 1 to 50 mg of water |
Indication | RUN AND END Display in Auto Mode |
K.F Flow | Highly Sensitive solenoid control valve for Automatic control of K.F. Reagent/ |
K.F Dispensing Resolution | 0.05 ml |
Detection | Current Sensing by Electronic Control. |
Measuring Electrode | Dual Platinum Electrode |
Titration Cell | Air Tight 200 ml, Glass vessel, |
End Point Delay | 30 seconds |
Timer | Adjustable Timer |
Stirrer | Variable speed magnetic stirrer with ON / off Control |
Buzzer | Yes |
Burette | Pressure filling auto zero burette with 0.05 ml. Resolution. |
Power Supply | 230 volts AC, +-10% , 50 Hz |